• Omron NX-Series Safety Network Controller
Fonctions

NX Series CIP Safety Controller with EtherCAT and Ethernet/IP capabilities

In addition to new hardware, Sysmac Studio new functions include Automatic Programming, Safety Data Logging, and Online Functional Test.

01-NX-SL5.jpg

Add-on or stand-alone CIP Safety

The NX-CSG320 is a communications controller that allows the NX-SL5_ series safety controllers to work independent of the machine control system for add-on safety or stand-alone safety network applications.

02-NX-SL5.jpg

Integrated control and safety with Safety over EtherCAT and CIP Safety on Ethernet/IP simultaneously

When used with the NX102 Machine Automation Controller the NX-SL5_ series Safety Controller can simultaneously communicate FSoE over EtherCAT and CIP Safety on Ethernet/IP at the same time allowing for unique application involving high-speed synchronous motion, machine to machine control or communication with remote devices utilizing the CIP Safety protocol over Ethernet/IP.

03-NX-SL5.jpg

Software enhancements to quicken design and verification of safety

Quicken design with Automatic Programming to get machines up and running fast by creating the bulk of basic programming. Make sure that logic works the first time with Simple Automatic Test, automatically test logic based on expected outcomes without the need of manual simulation. To complete the commissioning process the Online Functional Test, guarantees the operation and functionality of physically connected devices with this test function that runs within the programming software.

04-NX-SL5.jpg

Simplify troubleshooting and maintenance with data-logging

If a machine stops due to an intermittent false troubleshooting can be cumbersome, with data-logging log up to 100 inputs and quicken determine the stop cause and remedy the problem fast.

05-NX-SL5.jpg

Connect to 3rd Party CIP safety devices

Safety systems for industrial robots are becoming increasingly popular; networks can be easily built with the NX-CSG320 communications controller and NX-SL5 series Safety CPU Units which support CIP Safety.

Safety Troubleshooting Tool

Designed specifically with customers in mind, this tool for use with the NX-SL5 series safety CPUs and associated safety I/O in the locally mounted backplane, allows access for troubleshooting without the need of Sysmac Studio programming software.

This license-free software along with a copy of the Safety ENS file (created by Sysmac Studio), a user can perform the following maintenance functions.

NX-SL5 Troubleshooting Tool

NX-SL5 NA HMI Screen Samples and Practice Guide

Read the current Safety Signature of the controller

Verify that no changes have been made to the program or configuration.

NX-SL5_Safety_Troubleshooting_Tool1.jpg

Monitor safety I/O with graphic unit representation

The status of local and remotely mounted units can be monitored without opening the control cabinet.

NX-SL5_Safety_Troubleshooting_Tool2.jpg

Troubleshooting Tool

Provides the Event Name, Details of possible causes and a list of Action and corrections.

NX-SL5_Safety_Troubleshooting_Tool3.jpg

NA HMI Safety Troubleshooting Screens

Omron has created a series of pre-written screens available for use with our NA series of HMIs.  The screens allow for monitoring of a variety of functions and help quickly troubleshoot and determine the cause of problems including nuisances stops.

Safety Signature check

Verify the Safety Signature on start-up to ensure the program has not been changed or modified.

NX-SL5_Safety_Troubleshooting_Tool4.jpg

I/O Monitor

Monitor the condition and status of the IO of rack mounted units

NX-SL5_Safety_Troubleshooting_Tool5.jpg
NX-SL5_Safety_Troubleshooting_Tool6.jpg

Display Safety Data Log results

Help determine the stop cause with a time chart display on the HMI with on screen measurement capabilities

NX-SL5_Safety_Troubleshooting_Tool7.jpg

System Restore file transfer from HMI mounted USB drive

Transfer a system restore file to the NX102 / NX-CSG320 mounted memory card to restore a safety system (requires additional procedure on CPU as well)

NX-SL5_Safety_Troubleshooting_Tool8.jpg
Téléchargements

Brochures

Show all Brochures

Datasheets

Show all Datasheets

Manuals

Show all Manuals

Software tools

Show all Software tools

Tech notes

Show all Tech notes

Presentations

Show all Presentations

Certificates

Show all Certificates

Soutien technique

Obtenez les réponses et le soutien dont vous avez besoin pour favoriser l'évolution de votre entreprise.

1.866.986.6766

Recherche de distributeur

Nos distributeurs sont positionnés de façon à vous offrir un soutien technique et un service exceptionnels.

Trouver un distributeur

Formation

Nos programmes de formation vont des cours offerts dans nos installations aux formations sur site.

En savoir plus

Centre de ressources

Accéder aux fiches techniques, aux manuels, aux brochures, à la bibliothèque de CAD, aux outils logiciels et aux essais

En savoir plus